RECTIFIERS TYPE HBQG, 1500 - 15000 Amps.

Rectifiers type HBQG are developed for the quality conscious electro-plater, offering excellent performance and reliability.

 

 

 

 

Profitable investment

  • Units are compact
  • Very easy to install
  • No commisioning needed

Process optimized

  • High accuracy and low ripple
  • Easy of interface with computers
  • Wide range of options to suit your process

Low cost of operation

  • Minimum of maintenance
  • Air cooling; no costs for oil, water, etc.
  • Designed for automatic operation
  • Easy to service and repair

Secure and safe

  • Designed according to International standards
  • Extensive warranties
  • Service and spare parts available worldwide
  • Contains no dangerous oils etc.

FUNCTION

The mains voltage is applied to the main transformer (4) via the main contractor (1) and primary thyristors (3). The transformer provides isolation from the mains and transforms the voltage to the rated output level.
The secondary voltage/current is rectified through the diode bridge (6) which has a one-way six pulse connection with an interphase transformer (5).
This connection allows high efficiency with very low harmonic content. The control unit (8) measures actual DC-current by means of the shunt (7), actual DC-voltage, and controls the primary thyristors (3) until set and actual values correspond.
The control unit (8) measures the primary line current via current transformers (2) and in the event of overload the contactor is tipped.
Set values for current and voltage are supplied from a standard seperate control panel or can be supplied from an external control system. Standard signals are 0-10V for both current and voltage.

TECHNICAL DATA & STANDARD SIZES

Supply voltage : 3x380V, 50-60 Hz, other voltages on request.
Control accuracy : Voltage/current <1%.
Ambient temperature : Max 40 C. (at 55 C max 75% of nominal output current).
DC ripple : About 3% at rated load.
Regulation range : stepless - constant voltage/current 0-100%.

BLOCK SCHEMATIC DIAGRAM

Humidity : Max 85% relative.
Protections : Over-current, over-temperature, transient voltage and short circuit protected.
Duty ratio : Designed for continuous operation at rated load up to 1000 m altitude.
Compensation : Adjustable compensation function against secondary voltage drop (at CV mode).

OPTIONS :

  • Serial communication
  • Programable controller
  • A/D and D/A converters
  • Signal converters
  • Ah-counters
  • Process timers
  • 10-turns potentiometers
  • Pole reversing units
  • Control unit for pulse plating
  • Custom designed rectifiers
  • Extra ripple filter